🔌 Envertech Local – Cloud-Free Envertech Integration for Home Assistant

Local, cloud-free monitoring of Envertech micro-inverters via their TCP interface. The integration reads live data straight from your inverter or gateway on the local network – no cloud account needed, and nothing leaves your LAN.

Envertech logo

Integration domain envertech_local, shown in Home Assistant as Envertech API. Open source on GitHub and installable via HACS.

  • Home Assistant integration
  • Local polling
  • HACS custom repository
  • Energy Dashboard ready
  • MIT license
Category
💻 GitHub projects
Requirements
See section below
Code blocks
3
Read time
15 min read

Envertech Local keeps a persistent TCP connection to your Envertech inverter or gateway and turns the data into Home Assistant sensors: per-panel live values, system totals and daily, monthly and yearly energy. Everything is configured in the UI – no YAML required.

It is maintained by JimmyBones and uses the envertech-local protocol library.

Using the Envertech Solar Portal instead? If your system reports to the Envertech cloud and you just want portal values, have a look at the Envertech Solar cloud integration.

✨ Features

  • 🏠 100 % local: a persistent TCP connection to the inverter (default port 14889), polled every 5 seconds
  • 🔍 Automatic discovery of inverters on your network (UDP broadcast), with manual setup as a fallback
  • ⚡ Per-panel live values: DC input voltage, power, energy, temperature, grid voltage and grid frequency
  • 🏡 System totals: total power and lifetime energy
  • 📅 Daily, monthly and yearly energy sensors that survive restarts
  • 📈 Energy Dashboard ready: all energy sensors use device_class: energy and state_class: total_increasing
  • 🔁 Automatic reconnect with backoff (5 s up to 2 min) if the connection drops
  • 🌍 Translations: English, German and Polish
  • 🧩 Installable via HACS, with no YAML to write

📋 Requirements

  • Home Assistant 2024.6.0 or newer
  • An Envertech micro-inverter or gateway with a local TCP interface on port 14889, for example devices of the EMT series
  • Home Assistant must be able to reach the inverter on TCP port 14889
  • For automatic discovery: UDP broadcasts must work – usually the same subnet/VLAN and host networking for Docker installs
  • Recommended: a fixed IP address (DHCP reservation) for the inverter in your router

📦 Installation

HACS (recommended)

The integration is not in the HACS default list yet (the inclusion request hacs/default#10850 is pending). Until then, add it as a custom repository:

  1. In Home Assistant, open HACS → ⋮ (top right) → Custom repositories.
  2. Add the repository URL below with type Integration.
  3. Search for Envertech API in HACS and click Download.
  4. Restart Home Assistant.
Bash
https://github.com/JImmyB0nes/Envertech_localJBCODE, 'text', 'Custom repository URL'); ?>

      <h3>Manual installation</h3>
      <ol>
        <li>Download the <a href="<?= e($repo) ?>/releases/latest" target="_blank" rel="noopener">latest release</a>.</li>
        <li>Copy <code>custom_components/envertech_local</code> into <code>&lt;config&gt;/custom_components/</code> of your Home Assistant installation.</li>
        <li><strong>Restart</strong> Home Assistant.</li>
      </ol>

      <h2>⚙️ Configuration</h2>
      <p>The integration is set up entirely in the UI through a config flow:</p>
      <ol>
        <li>Go to <strong>Settings → Devices &amp; services → Add integration</strong> and choose <strong>Envertech API</strong>.</li>
        <li><strong>Discovery:</strong> the integration spends about 5 seconds searching your network for inverters. It sends UDP broadcasts on ports <code>48889</code> (Ethernet/LOCALCON) and <code>48899</code> (Wi-Fi). Every inverter found is listed as <code>IP — serial number</code>, except those already set up.</li>
        <li>Pick your inverter and check the <strong>TCP port</strong> (default <code>14889</code>).</li>
        <li>If nothing is found, choose <strong>Manual entry</strong> and enter the values from the table below.</li>
        <li>Add one config entry for each inverter/gateway. The serial number is the unique ID, so an inverter can’t be added twice.</li>
      </ol>
      <div class="table-wrap"><table>
        <thead><tr><th scope="col">Field (manual entry)</th><th scope="col">Description</th><th scope="col">Example / default</th></tr></thead>
        <tbody>
          <tr><td>IP address</td><td>IP address of the inverter/gateway</td><td><code>192.168.1.50</code></td></tr>
          <tr><td>Serial number</td><td>The 8-character hex ID of the inverter</td><td><code>9A1B2C3D</code></td></tr>
          <tr><td>TCP port</td><td>Local TCP port of the inverter</td><td><code>14889</code></td></tr>
        </tbody>
      </table></div>
      <p>After setup, the inverter-wide sensors show up right away. Per-panel sensors are added automatically once the first data packet reports the panels. Until data arrives, sensors are <code>unavailable</code>.</p>

      <h2>📊 Sensors</h2>
      <p>The integration creates <strong>one device per config entry</strong> (<code>Envertech API &lt;serial&gt;</code>, manufacturer <em>JimmyBones</em>, model <em>Microinverter</em>). The firmware version is shown as the device’s software version.</p>

      <h3>Per panel / module</h3>
      <p>These are created for every panel <code>n</code> (1, 2, …) that the inverter reports. The entity names are <code>P&lt;n&gt; …</code>, e.g. <code>sensor.p1_power</code>. With more than one inverter, Home Assistant adds a numeric suffix to entity IDs that would otherwise be identical.</p>
      <div class="table-wrap project-table"><table>
        <thead><tr><th scope="col">Sensor (entity name)</th><th scope="col">Key</th><th scope="col">Unit</th><th scope="col">Device / state class</th><th scope="col">Notes</th></tr></thead>
        <tbody>
          <tr><td>🔌 <code>P&lt;n&gt; Input Voltage</code></td><td><code>input_voltage</code></td><td>V</td><td>voltage / measurement</td><td>DC input voltage of the panel</td></tr>
          <tr><td>⚡ <code>P&lt;n&gt; Power</code></td><td><code>power</code></td><td>W</td><td>power / measurement</td><td>Current power of the panel/module</td></tr>
          <tr><td>🔋 <code>P&lt;n&gt; Energy</code></td><td><code>energy</code></td><td>kWh</td><td>energy / total_increasing</td><td>Lifetime energy of the module</td></tr>
          <tr><td>🌡️ <code>P&lt;n&gt; Temperature</code></td><td><code>temperature</code></td><td>°C</td><td>temperature / measurement</td><td>Temperature reported by the micro-inverter module</td></tr>
          <tr><td>🏭 <code>P&lt;n&gt; Grid Voltage</code></td><td><code>grid_voltage</code></td><td>V</td><td>voltage / measurement</td><td>AC grid voltage measured by the module</td></tr>
          <tr><td>〰️ <code>P&lt;n&gt; Frequency</code></td><td><code>frequency</code></td><td>Hz</td><td>frequency / measurement</td><td>AC grid frequency</td></tr>
          <tr><td>🆔 <code>P&lt;n&gt; Module Serial</code></td><td><code>mi_sn</code></td><td>–</td><td>–</td><td><em>Diagnostic</em> entity: serial number of the module</td></tr>
        </tbody>
      </table></div>
      <p>Every per-panel sensor also has a <code>serial_number</code> attribute containing the module serial.</p>

      <h3>Inverter / system</h3>
      <p>These sensors belong to the device. Their names are translated (English, German, Polish). With Home Assistant set to English, the entity IDs look like <code>sensor.envertech_api_&lt;serial&gt;_total_power</code>.</p>
      <div class="table-wrap project-table"><table>
        <thead><tr><th scope="col">Sensor</th><th scope="col">Key</th><th scope="col">Unit</th><th scope="col">Device / state class</th><th scope="col">Notes</th></tr></thead>
        <tbody>
          <tr><td>⚡ Total power</td><td><code>total_power</code></td><td>W</td><td>power / measurement</td><td>Sum of all panel powers</td></tr>
          <tr><td>🔋 Total energy</td><td><code>total_energy</code></td><td>kWh</td><td>energy / total_increasing</td><td>Sum of all panel lifetime energies</td></tr>
          <tr><td>📅 Daily energy</td><td><code>energy_daily</code></td><td>kWh</td><td>energy / total_increasing</td><td>Energy since local midnight</td></tr>
          <tr><td>🗓️ Monthly energy</td><td><code>energy_monthly</code></td><td>kWh</td><td>energy / total_increasing</td><td>Energy in the current month</td></tr>
          <tr><td>📆 Yearly energy</td><td><code>energy_yearly</code></td><td>kWh</td><td>energy / total_increasing</td><td>Energy in the current year</td></tr>
          <tr><td>🧠 Firmware version</td><td><code>firmware_version</code></td><td>–</td><td>–</td><td><em>Diagnostic</em> entity, format <code>x/y</code></td></tr>
        </tbody>
      </table></div>
      <p>Numbers are rounded to 2 decimal places. The <strong>daily, monthly and yearly</strong> sensors are derived from <em>Total energy</em>: when a new period starts, they store the current total as an offset. They keep <code>offset</code>, <code>period_marker</code> and <code>last_reset</code> as attributes and restore them after a restart, so values don’t jump back to zero when Home Assistant restarts.</p>
      <?php note('The integration does <strong>not</strong> provide per-panel current (A), per-panel AC power or MPPT-specific values, because the inverter’s local protocol doesn’t report them.', 'info'); ?>

      <h2>📈 Energy Dashboard</h2>
      <ol>
        <li>Open <strong>Settings → Dashboards → Energy</strong>.</li>
        <li>Under <strong>Solar panels</strong>, click <strong>Add solar production</strong>.</li>
        <li>Select <code>sensor.envertech_api_&lt;serial&gt;_total_energy</code> (<em>Total energy</em>). For per-module statistics, add the individual <code>P&lt;n&gt; Energy</code> sensors instead.</li>
      </ol>
      <?php note('Use <em>Total energy</em> rather than the daily/monthly/yearly sensors – the Energy Dashboard does its own period calculations. The period sensors are meant for cards and automations.', 'tip'); ?>

      <h2>🛠️ Troubleshooting</h2>
      <details class="project-faq">
        <summary>No values after a Home Assistant restart (only a reload helped)</summary>
        <div class="project-faq-body">
          <p>Versions <strong>≤ 1.1.1</strong> could end up without values after a restart: if the inverter wasn’t reachable within 60 seconds of startup (for example at night or because the network wasn’t up yet), the sensors were never created, and a dropped or silent TCP connection was never re-established.</p>
          <p>This is fixed in <strong>1.1.2</strong>: the connection reconnects automatically with backoff (5 s up to 2 min), sensors are created immediately and stay <code>unavailable</code> until data arrives, and new panels are added as soon as they report. Update to the latest version; if it still happens, enable debug logging (see below) and open an issue.</p>
        </div>
      </details>
      <details class="project-faq">
        <summary>Sensors are <code>unavailable</code> at night</summary>
        <div class="project-faq-body"><p>Micro-inverters are powered by the panels, so they switch off when there is no sunlight. The sensors become <code>unavailable</code> while the inverter is offline and recover on their own in the morning. The energy totals are unaffected.</p></div>
      </details>
      <details class="project-faq">
        <summary>No inverter found during setup</summary>
        <div class="project-faq-body">
          <ul>
            <li>Discovery relies on UDP broadcast, which doesn’t cross VLANs/subnets or Docker bridge networks. Use <strong>Manual entry</strong> instead.</li>
            <li>Check that the inverter is powered (daylight!) and connected to your network.</li>
            <li>Check that port <code>14889</code> is reachable:</li>
          </ul>
          <?php code_block(<<<'JBCODE'
nc -vz <inverter-ip> 14889
Per-panel sensors are missing

Panel sensors are created when the inverter first reports the panel. If the inverter was offline during setup, they appear automatically as soon as it sends data. No reload is needed from 1.1.2 on.

Enable debug logging

Add this to configuration.yaml and restart:

YAML
logger:
  default: info
  logs:
    custom_components.envertech_local: debug
    envertech_local: debug

Alternatively use Settings → Devices & services → Envertech API → ⋮ → Enable debug logging, reproduce the problem and then disable it again to download the log.

🔧 Supported devices

The integration supports Envertech micro-inverters and gateways with a local TCP interface on port 14889, for example devices of the EMT series. It is designed for systems with multiple panels.

Your model doesn’t work or reports different data? Please open an issue and include the model, the firmware version and, if possible, anonymized debug logs.

🤝 Contributing & credits

Bug reports, ideas and pull requests are welcome. The unit tests run locally without Home Assistant:

Bash
pip install pytest && pytest -q

Released under the MIT License.

Envertech Local on GitHub

Source code, releases, issues and the full README.

View on GitHub (opens in a new tab)